Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 188-192, 2021.
Article in Japanese | WPRIM | ID: wpr-886207

ABSTRACT

Ascites is a rare sign of aortic valve disease. Here, we report two cases of refractory ascites that had resulted from aortic stenosis and insufficiency and consequently improved after aortic valve replacement. The first case was a 44-year-old female who had undergone aortic valve repair for aortic stenosis 15 years earlier. She complained of dyspnea and severe abdominal distension due to unimproved massive ascites despite medical therapy. She was diagnosed with aortic stenosis and insufficiency and functional tricuspid insufficiency as well as complete atrioventricular block. She underwent mechanical aortic valve replacement, tricuspid annuloplasty and DDD pacemaker implantation. The second case was a 61-year-old man with a history of alcoholic liver disease who had been hospitalized for massive ascites, progressing rapidly in spite of aggressive medical therapy. Echocardiography revealed severe aortic stenosis and insufficiency; thus, he underwent bioprosthetic aortic valve replacement. Both patients were completely free from ascites about 6 months after surgery.

2.
Japanese Journal of Cardiovascular Surgery ; : 267-271, 2018.
Article in Japanese | WPRIM | ID: wpr-688466

ABSTRACT

SOLO SMART is a stentless bioprosthesis that comprises a larger effective orifice area and reduced pressure gradient, exhibiting a better hemodynamic profile than a stented bioprostheses. Currently, SOLO SMART finds application in patients with aortic valve diseases. However, patients with bicuspid aortic valve disease may present Valsalva sinus asymmetry. Recently, some studies have considered SOLO bioprosthesis as contraindicated in patients with a bicuspid aortic valve. Here, we report the case of a 79-year-old female with bicuspid aortic stenosis and Valsalva sinus asymmetry. We preoperatively assessed the aortic root of the patient using a novel 3D workstation that creates virtual reality (VR) images from cardiac CT data. After creating three symmetric commissures at the wall of the Valsalva sinus, we evaluated the distance from the coronary orifices. We determined the appropriate suture line of bioprosthesis avoid coronary orifice occlusion. Aortic valve replacement with SOLO SMART was successful, and the postoperative clinical course was uneventful. Hence, preoperative evaluation of the aortic root using VR images could be a precise and useful method for the assessment of the operative indication for SOLO SMART.

3.
Japanese Journal of Cardiovascular Surgery ; : 49-52, 2012.
Article in Japanese | WPRIM | ID: wpr-376900

ABSTRACT

We reported a 74-year-old female complicated by ostial obstruction of the left main trunk after aortic valve replacement for severe aortic stenosis. At surgery, the length from the orifice of the left main trunk to the aortic annulus was 3 mm. After a 19 mm Carpentier-Edwards PERIMOUNT MAGNA was implanted in supra-annular position, the orifice of left main trunk was concealed by a sewing cuff of the bioprosthesis. Before aortic declamping, saphenous vein graft was bypassed to the left anterior descending artery. The postoperative course was uneventful. Computed tomography demonstrated the ostial obstruction of the left main trunk by the bioprosthesis.

4.
Japanese Journal of Cardiovascular Surgery ; : 215-218, 2012.
Article in Japanese | WPRIM | ID: wpr-362948

ABSTRACT

A 81-year old woman had hypertensive heart failure. She had a history of intermittent claudication for 5 years. Her ankle brachial pressure index (ABI) was 0.53 on the right and 0.58 on the left side. Coarctation of the descending aorta with severe calcification was found by a whole body CT. After medical therapy for heart failure, axillo-bifemoral artery bypass using an 8 mm ringed expanded polytetrafluoroethylene (ePTFE) graft was performed. Postoperatively, ABI improved to 0.83 on the right and 0.87 on the left side. The patient is doing well without any signs of heart failure or intermittent claudication. Although it is a palliative operation, axillo-bifemoral artery bypass is an effective and less-invasive procedure and appropriate for elderly patients.

5.
Japanese Journal of Cardiovascular Surgery ; : 264-267, 2008.
Article in Japanese | WPRIM | ID: wpr-361842

ABSTRACT

A 54-year-old woman complained of prolonged fever. Echocardiography showed severe mitral regurgitation with vegetation, and computed tomography showed right coronary artery (RCA) fistula to the coronary sinus (CS). Blood culture revealed Strep. viridans, thus a diagnosis of active infective endocarditis was established. The patient underwent urgent surgery. Surgical findings showed that vegetation was located in A3 to P3 of the mitral valve. The patient underwent mitral valve repair using a glutalualdehyde-treated autologous pericardial patch and artificial chordea. Epicardial ligation for fistula was performed. Her postoperative course was uneventful.

6.
Japanese Journal of Cardiovascular Surgery ; : 188-192, 2007.
Article in Japanese | WPRIM | ID: wpr-367265

ABSTRACT

A 44-year-old man with a history of remittent fever for 6 months was given a diagnosis of inf ective endocarditis of the aortic valve related to a congenital ventricular septal defect (VSD), although no bacterial growth was obtained by blood culture. After one week of antibiotic treatment, aortic valve replacement (AVR) and patch closure of the VSD were performed after debridement of infected tissue and vegetations involving the aortic root, pulmonary and tricuspid valves, and myocardium surrounding the VSD. Antibiotic treatment was continued postoper-atively, but elevation of C-reactive protein (CRP) persisted. Blood culture disclosed Candida albicans in the blood 3 months after AVR. Fungal prosthetic valve endocarditis (PVE) was suspected, therefore, aortic root replacement with a Free Style bioprosthesis and VSD re-closure were performed followed by continued systemic antifungal treatment. Five months after reoperation, the patient was readmitted with a high fever. A pseudoaneurysm of the left common iliac artery and complete obstruction of the external iliac artery were shown by contrast-enhanced computed tomography (CT). The aneurysm was resected without revascular-ization. This case presentation concludes that long-term whole body study with contrast-enhanced CT might be necessary even though complete eradication of the infected foci of the heart has been established.

7.
Japanese Journal of Cardiovascular Surgery ; : 231-234, 2004.
Article in Japanese | WPRIM | ID: wpr-366976

ABSTRACT

Between 1987 and 2002, 22 internal iliac artery aneurysms in 14 patients were repaired. In 13 we performed aneurysm excision or reconstruction. There were 3 cases in which simple proximal ligation of the internal iliac artery was performed; in 2 of these CT scans confirmed that the reduction of the internal iliac artery aneurysms was not recognized, but blood flow was not shown in the aneurysm. However, 6 years postoperatively 1 patient was confirmed with an expansion of the aneurysm, and blood flow was seen on a CT scan. In the 2 latest patients, the blood pressure of the internal iliac artery was measured before and after proximal clamping of the internal iliac artery, but the blood pressure of aneurysms could not be fully lowered by proximal ligation of the internal iliac artery. Therefore, endoaneurysmorrhaphy seemed to be the operative method of choice for treatment of the internal iliac artery aneurysms.

SELECTION OF CITATIONS
SEARCH DETAIL